  • Analysis of N Series Models
    equipment status Cause Analysis Check repair Note
    Machine is not powered 1. Whether the power plug is plugged in properly
    2. Whether the socket has 220V AC power
    3. Is the fuse normal?
    Connect to 220V / 50Hz power supply
    No ozone 1. Check if the circuit is normal
    2. Whether the power is discharged
    3. Inspect the ceramic sheet for damage or aging

    1. Replace the power supply

    2. Replace the ceramic sheet

    There is high voltage in the box,
    If you need to open the backplane, please operate under power off
    Reduced ozone concentration 1. Check if the ceramic sheet is all discharged Replace ceramic plate
    There is power on the case 1. The power supply is not grounded
    2. The air is too humid
    Repair circuit
    2. Move the ozone machine to a dry and ventilated place

    Burning or tripping of fuse due to ozone generator opening Short circuit
    2.Ozone discharge module is damaged
    Repair circuit
    2. Replace the ozone discharge module


  • Analysis of common faults of ABY models
    equipment status Cause Analysis Check repair Note
    Machine is not powered 1. Whether the power plug is plugged in properly
    2. Whether the socket has 220V AC power
    3. Is the fuse normal?
    Connect to 220V / 50Hz power supply
    No gas output from ozone output 1. Whether the internal circuit connector of the machine is disconnected
    2. Whether the pipeline is discounted
    3.Air pump switch may not be turned on
    1. In case of power failure, open the back cover of the case and check the pipeline
    2.Turn on the air pump switch
    There is high voltage in the box,
    If you need to open the backplane, please operate under power off
    Ozone output has gas output but no ozone 1.Ozone switch is not turned on
    2.Ozone discharge module is damaged
    1. Turn on the air pump switch
    2. Check if the circuit is normal
    3. Replace the ozone discharge module

    There is power on the case 1. The power supply is not grounded
    2. The air is too humid
    Repair circuit
    2. Move the ozone machine to a dry and ventilated place

    Burning or tripping of fuse due to ozone generator opening Short circuit
    2.Ozone discharge module is damaged
    Repair circuit
    2. Replace the ozone discharge module

    Water inside the machine

    1. Water returns to the ozone discharge tube during water treatment

    2. The air is humid

    1. Dry the water in the discharge tube
    2. Dry the water inside the case
    In this case, stop immediately.
    Reuse after processing